Skip to content
All resources

Article

MOSFET Junction Temperature Calculation: When the RDS(on) Loop Settles and When It Runs Away

MOSFET junction temperature calculation: why on-resistance alone can't run a switching MOSFET away before Tj(max) from room temperature up, and why the loop gain still multiplies your Rθ error.

Philip Bassett
mosfetlearningthermal

A MOSFET's junction temperature depends on its loss, and its loss depends on its junction temperature. On-resistance rises as the die heats, so the conduction loss rises with it. The usual advice is to iterate: guess a temperature, work out the loss, work out the temperature, repeat. TI's load-switch datasheets say "Two or three iterations are generally sufficient" [1]. Our own buck converter losses article says only that it "converges, hopefully".

From room temperature up, on-resistance alone can't run a switching MOSFET away before it reaches its maximum junction temperature. That follows from a three-line bound, and it holds for every silicon, SiC and GaN part I checked. Below freezing the steepest parts can cross it. What the loop does do, at any temperature, is multiply the error in your thermal resistance. That error is usually the largest in the calculation, so the number worth knowing is how much the loop multiplies it.

The loop

At a steady operating point the junction sits where the heat the part makes equals the heat its thermal path carries away:

Tj=Ta+Rθ P(Tj)T_j = T_a + R_\theta \, P(T_j)

where:

  • TjT_j is the junction temperature, in °C
  • TaT_a is the ambient temperature, in °C
  • RθR_\theta is the thermal resistance from junction to ambient, in °C/W
  • P(Tj)P(T_j) is the switch's total loss at that junction temperature, in W

The temperature appears on both sides, which is why it has to be solved rather than calculated. How hard it is to solve depends on one number, the loop gain:

g=Rθ dPdTjg = R_\theta \, \frac{dP}{dT_j}

where gg is dimensionless and RθR_\theta is the thermal resistance in °C/W. dP/dTjdP/dT_j is how fast the loss PP rises with the junction temperature TjT_j, in W/°C.

It answers one question. If the junction ran one degree hotter, what fraction of that degree would its own extra loss put back? At gg = 0.1 the part returns a tenth of a degree, and the loop settles quickly. At gg = 1 every degree returns a whole degree. There's no stable temperature, and that's thermal runaway. onsemi's AND8223 states the same condition graphically, as the device line becoming tangent to the system line [2].

The gain also says how fast an iteration settles. Each pass shrinks the remaining error by a factor of gg. If gg is small, two or three passes are plenty, which is where TI's rule comes from. If gg is 0.7, the error falls by less than a third each pass. At 0.72, in the example below, it takes twenty passes to get within half a degree. Slow convergence is a warning in its own right.

And it gives a one-step answer that needs no iteration:

Tj≈Ta+Rθ P(Ta)1−gaT_j \approx T_a + \frac{R_\theta \, P(T_a)}{1 - g_a}

where TjT_j, TaT_a and RθR_\theta are as above and P(Ta)P(T_a) is the loss with the junction at ambient. gag_a is the loop gain evaluated at ambient. You can get gag_a before solving anything, from the cold conduction loss and the on-resistance slope below. The formula is exact when the loss rises linearly with temperature. A real loss curves upward, so it reads low, and the more so as gg grows. The worked example shows by how much.

The RDS(on) temperature coefficient

Datasheets plot normalised on-resistance against junction temperature. The MOSFET loss calculator reads it as a power law through 25 °C and one hot point:

RDS(on)(Tj)=RDS(on),25(Tj+273.15298.15)αR_{DS(on)}(T_j) = R_{DS(on),25} \left(\frac{T_j + 273.15}{298.15}\right)^{\alpha}

where RDS(on)(Tj)R_{DS(on)}(T_j) is the on-resistance at junction temperature TjT_j, RDS(on),25R_{DS(on),25} is its value at 25 °C, and α\alpha is a dimensionless exponent. The 273.15 converts °C to kelvin, so 298.15 is 25 °C.

Two datasheet points fix α\alpha. Infineon's BSC0901NSI reads 1.498 times its 25 °C value at 125 °C, which gives α\alpha = 1.40. Across the silicon MOSFETs in the switchmode.io catalogue in November 2026, α\alpha runs from 0.95 to 1.97, with a median of 1.41. The old rule of 0.5 %/°C describes the same curves well over the usual range.

Real curves bend upward, though. Near the maximum junction temperature they rise faster than a two-point fit says. BSC0901NSI doubles its on-resistance every 210 °C on its fitted power law, but every 164 °C on its own curve between 125 and 150 °C. That matters below.

The ceiling on the loop gain

Split the switch's loss into its separate terms:

P(Tj)=∑iPi(Tj)P(T_j) = \sum_i P_i(T_j)

where P(Tj)P(T_j) is the total loss and Pi(Tj)P_i(T_j) is one term of it, such as conduction, gate drive or diode conduction in the dead time.

Each term rises with temperature at its own fractional rate:

si=1PidPidTjs_i = \frac{1}{P_i} \frac{dP_i}{dT_j}

where sis_i is the fractional slope of term PiP_i with junction temperature TjT_j, in 1/°C. A term that doubles every DD degrees has si=0.693/Ds_i = 0.693/D, where 0.693 is the natural log of 2. A term that doesn't move with temperature has si=0s_i = 0.

All of the loss leaves through the thermal path, so RθP=Tj−TaR_\theta P = T_j - T_a at the solved temperature. Put that into the definition of gg:

g=(Tj−Ta)∑iPiP sig = (T_j - T_a) \sum_i \frac{P_i}{P} \, s_i

where:

  • gg is the loop gain
  • Tj−TaT_j - T_a is the temperature rise, in °C
  • Pi/PP_i/P is each term's share of the total loss
  • sis_i is that term's fractional slope, in 1/°C

That's exact, for one lumped thermal resistance that doesn't itself change with temperature, and a load current the converter holds fixed. The loop gain is the temperature rise times the loss-weighted fractional slope. A term contributes only in proportion to its share of the loss and how steeply it rises.

For conduction the inductor sets the current, so the conduction loss PcondP_{cond} scales exactly as RDS(on)R_{DS(on)} does. Its fractional slope sconds_{cond} is on-resistance's own. If conduction is the only term that moves:

g=PcondP scond (Tj−Ta)≤scond (Tj−Ta)g = \frac{P_{cond}}{P} \, s_{cond} \,(T_j - T_a) \le s_{cond} \,(T_j - T_a)

where:

  • gg is the loop gain
  • Pcond/PP_{cond}/P is conduction's share of the total loss PP
  • sconds_{cond} is the fractional slope of RDS(on)R_{DS(on)} at TjT_j, in 1/°C
  • Tj−TaT_j - T_a is the temperature rise, in °C

On the power law, scond=α/(Tj+273.15)s_{cond} = \alpha/(T_j + 273.15). The bound is reached only when conduction is the whole loss. Every milliwatt of fixed loss pushes gg further below it.

Superconducting detector physics uses the same loop gain for a current-biased sensor heating its own resistance, with the same gg < 1 condition for stability [3]. I haven't found the bound stated for a MOSFET.

The ceiling rises with the temperature rise, so it's highest at the part's maximum junction temperature, Tj(max)T_{j(max)}. I read sconds_{cond} off each datasheet curve over its last 25 °C below Tj(max)T_{j(max)}, for every part in the catalogue. Fig. 1 shows the result.

Fig. 1. The conduction-only ceiling on the loop gain at each part's maximum junction temperature, from each datasheet curve's own slope, for 99 silicon, 113 SiC and 8 GaN MOSFETs, at 25 °C and −40 °C ambient
Fig. 1. The ceiling on gg at each part's Tj(max)T_{j(max)}, from each datasheet curve's own slope there. Teal is 25 °C ambient and black is −40 °C. At 25 °C nothing reaches 1. At −40 °C a quarter of the silicon parts do.

At 25 °C ambient, no part of any technology reaches 1. Silicon tops out at 0.85, with a median of 0.57. SiC tops out at 0.70 and GaN at 0.93. At 50 °C, silicon is at most 0.71. So from room temperature up, a switching MOSFET whose only moving loss is conduction reaches Tj(max)T_{j(max)} before its loop gain reaches 1.

Nexperia's AN11158 puts the usual view plainly. Power MOSFETs "are often considered to be immune to thermal runaway due to the temperature coefficient of resistance" [4]. Its reason is that "as temperature rises, current falls", and it adds that this is "not the whole story". In a converter the current doesn't fall, because the inductor holds it. The feedback is positive, and gg is greater than zero. From room temperature up the immunity holds anyway, because of the ceiling.

Below freezing it doesn't. The ceiling climbs as the ambient falls, because the junction then has further to rise. The steepest silicon part, ISC151N08NM6, reaches 1 at an ambient of about 0 °C. At −40 °C, 26 of the 99 silicon parts cross, all of them rated to 175 °C. GaN crosses below about 15 °C, and six of the eight GaN parts with a published curve are over 1 at 0 °C. SiC holds until about −39 °C. A part that cold has to dissipate a lot to reach Tj(max)T_{j(max)}, but a sealed enclosure in a cold climate can ask for exactly that.

A worked example: 12 V to 3.3 V at 10 A

The buck converter design example is a 12 V ±10 % to 3.3 V, 10 A synchronous buck at 500 kHz. It has a 1.5 µH inductor, a 5 V gate drive and 50 °C ambient. Infineon's BSC024NE2LS is the high side and BSC0901NSI the low side [5], [6]. The low side conducts for about three quarters of each period, so it carries the conduction story.

I solved it in the MOSFET power loss calculator at 13.2 V, with each datasheet's 4.5 V figures. Each switch has the calculator's default 50 °C/W. Dead time and driver resistance are left blank, so the calculator assumes 50 ns and 2 Ω / 1 Ω. This link opens it with every box filled.

At 10 A the low side loses 471 mW and settles at 73.6 °C. Only 196 mW of that is conduction. The other 275 mW is body-diode conduction in the dead time, which the calculator holds fixed. A real body diode's forward voltage falls by a millivolt or two per degree, so that term pulls the real gg down a little. The loop gain is 0.040. The iteration lands within 0.1 °C in two passes, and TI's rule is right here. The high side runs at 73.3 °C with gg = 0.016. Most of its loss is switching and output capacitance, which this calculator doesn't move with temperature.

Fig. 2 shows the same solve as a crossing. The black line is the junction temperature. Each curve is Ta+RθP(Tj)T_a + R_\theta P(T_j), the temperature the loss would hold the junction at. Where they cross, the two agree.

Fig. 2. The low side's junction temperature as the crossing of heat in, ambient plus thermal resistance times loss, with heat out, at 10 A, 23 A and 30 A
Fig. 2. BSC0901NSI at 50 °C/W and 50 °C ambient. Each curve crosses the line once, at 74 °C for 10 A, 150 °C for 23 A and 245 °C for 30 A. The curves bend upward too slowly to become tangent anywhere near Tj(max)T_{j(max)}.

Now push the load. The calculator's derating finds the low side reaches 150 °C at 23.0 A, and says the limit is Tj(max)T_{j(max)}, not runaway. There the loop gain is 0.226. The ceiling on the calculator's own power law is 0.330, and the gap is the fixed loss. Fig. 3 follows both along the load.

Fig. 3. The low side's junction temperature and loop gain against load current, with the maximum junction temperature, the 23 A maximum load and the conduction-only ceiling
Fig. 3. The low side's TjT_j (top) and gg (bottom) against load current, from the calculator. Its gg stays under the ceiling on its own power law all the way, and both are far from 1 when TjT_j reaches 150 °C at 23.0 A.

The calculator's two-point fit reads the slope low near the limit. On BSC0901NSI's own curve the ceiling at 150 °C is 0.42, and gg at 23 A would be about 0.29. That's a fix the calculator needs, and it's queued. It doesn't change the verdict here.

At 23 A the iteration needs four passes to get within half a degree, so "two or three" is a little short. The one-step formula with gag_a = 0.203 gives 148.5 °C against the solved 150 °C. A single pass from cold gives 128.6 °C, which is 21 °C low. Push on to 30 A and the one-step formula reads 11 °C low, as gg grows past 0.4.

Keep going and the calculator eventually reports runaway, at 37 A. Don't read that as gg reaching 1. At 36.5 A the low side solves at 492 °C with gg = 0.72. At 37 A the answer passes the solver's 500 °C cap, beyond which a junction temperature means nothing, and it stops there. Turning up the thermal resistance tells the same story. At 10 A the low side reaches 150 °C at about 190 °C/W and still settles, at 330 °C, at 400 °C/W.

What the loop gain is for

If runaway isn't the risk, the loop gain still matters, because it multiplies an error. Differentiate the first equation with respect to the thermal resistance:

dTjdRθ=P1−g\frac{dT_j}{dR_\theta} = \frac{P}{1 - g}

where dTj/dRθdT_j/dR_\theta is the shift in junction temperature TjT_j per °C/W of thermal resistance RθR_\theta. PP is the loss at the solved temperature, and gg is the loop gain there.

Without the loop, an error in RθR_\theta moves the temperature rise by the same fraction. With it, the fraction is multiplied by 1/(1−g)1/(1 - g). And RθR_\theta is the least certain number in the whole calculation. A datasheet's junction-to-ambient figure is measured on a JEDEC test board, not yours. TI's SPRA953D calls using it that way "a misapplication", because "the test board is a heat sink" [7].

At the 23 A point, gg is 0.226. Raise RθR_\theta by 20 %, from 50 to 60 °C/W, and the 100 °C rise becomes 127.6 °C. That's 27.6 % for a 20 % error, and the junction lands at 177.6 °C, well past its rating. The 1/(1−g)1/(1 - g) estimate gives 25.8 %. It's a linearisation, so it reads a little low for an error this size.

You can read gg off the calculator today without seeing it printed. Step RθR_\theta by 2.5 °C/W either side of your value and note TjT_j at each. Then

g=1−P ΔRθΔTjg = 1 - \frac{P \,\Delta R_\theta}{\Delta T_j}

where gg is the loop gain and PP is the switch's loss on its result tile. ΔRθ\Delta R_\theta is the 5 °C/W between the two steps, and ΔTj\Delta T_j is the difference in junction temperature between them, in °C. At 23 A, 47.5 and 52.5 °C/W give 143.6 and 156.6 °C, against 2.00 W. That's gg = 0.231, against the solver's 0.226.

Where runaway does come from

The identity says what it takes. To reach gg = 1 before Tj(max)T_{j(max)}, the loss-weighted slope has to pass 1/(Tj(max)−Ta)1/(T_{j(max)} - T_a). A term that made up the whole loss would have to double in fewer than 0.693 (Tj(max)−Ta)0.693 \,(T_{j(max)} - T_a) degrees. For a 150 °C part that's every 69 °C at 50 °C ambient. It's every 87 °C at 25 °C and every 104 °C at 0 °C. Here's how fast the candidates double near their hot end:

Loss termDoubles everySource
On-resistance, steepest silicon in the catalogueabout 122 °Ccatalogue curves
On-resistance, BSC0901NSIabout 164 °C[6]
Recovery charge, four Infineon 40–100 V parts178 °C or longer[8]–[11]
Recovery charge, TI's rule of thumb100 °C[12]
Schottky leakage, Vishay SS8PH1011 °C[13]
Integrated Schottky-like diode, BSC0901NSI13 to 18 °C[6]

Recovery charge isn't the steep term it's often taken for, on the evidence I found. Four datasheets print it hot, all from one Infineon family, at a slow 100 A/µs and about 100 A. At 125 °C they show 1.00 to 1.48 times the 25 °C value [8]–[11]. TI's Steve Widener warns that it "could double (or more)" at 125 °C [12]. A doubling every 100 °C is steeper than on-resistance, but it's short of the threshold from room temperature up. And its loop doesn't close on one switch. The charge is set by the low side's temperature, but most of its energy is dissipated in the high side. Body Diode Reverse Recovery Loss works through why. It heats the other die, and the loop closes only through copper the two share. The calculator gives each switch its own thermal resistance and takes one 25 °C figure for the charge, so it doesn't model that loop.

Schottky leakage is the term fast enough. Vishay's SS8PH10 leaks 0.18 µA at 25 °C and 110 µA at 125 °C, at its rated 100 V [13]. That's a doubling every 11 °C. A 16 % share of a part's loss is enough for it to reach gg = 1 on its own, at 150 °C from 50 °C ambient. It's why onsemi's AND8223 works its runaway example on a rectifier's leakage [2].

The example's low side has some of this. BSC0901NSI integrates a "schottky-like diode". Its leakage curve runs from about 26 µA at 25 °C to 3.2 mA at 125 °C, at 24 V [6]. While it blocks at 13.2 V near 150 °C, that's roughly 10 mW. It adds about 0.02 to the low side's gg at the 23 A point. Read at 24 V, the datasheet's figures put it at 0.09. Either way the part reaches Tj(max)T_{j(max)} first, but this is a term the calculator doesn't model.

One more mechanism shares the name. A MOSFET held below its zero-temperature-coefficient gate voltage takes more current as it heats, and one cell can take over the die. That's linear-mode runaway, in hot-swap and inrush circuits. onsemi's AND90187 says it "can only happen if the device is operating in saturation" [14]. It's a different device law on a switch that isn't switching, and nothing on this page applies to it.

The job this page leaves undone is the coupling. It solves each switch against its own thermal resistance, but on a real board the two share copper, so each one's loss heats the other. The recovery loop closes only there, and the loop gain that matters is the coupled one. switchmode.io is being built to solve a board's parts as one thermal network, and to report the loop gain each shared path actually closes.

References

[1] Texas Instruments, "TPS2560 Dual-Channel Precision Adjustable Current-Limited Power Switches," datasheet, sec. 11.1.1. [Online]. Available: https://ti.com/document-viewer/TPS2560/datasheet/GUID-15AAEA9D-4C24-49A0-A633-93E669EC28DF

[2] R. P. Stout, "Predicting Thermal Runaway," ON Semiconductor, AND8223/D, Rev. 0, Apr. 2006. [Online]. Available: https://www.onsemi.com/pub/collateral/AND8223-D.PDF

[3] M. De Lucia et al., "Transition Edge Sensors: Physics and Applications," arXiv:2411.01968, Nov. 2024. [Online]. Available: https://arxiv.org/pdf/2411.01968

[4] Nexperia, "Understanding power MOSFET data sheet parameters," AN11158, Rev. 7.0, Feb. 18, 2025. [Online]. Available: https://assets.nexperia.com/documents/application-note/AN11158.pdf

[5] Infineon Technologies, "BSC024NE2LS," product page and datasheet. [Online]. Available: https://www.infineon.com/part/BSC024NE2LS

[6] Infineon Technologies, "BSC0901NSI OptiMOS Power-MOSFET 30 V," datasheet, Rev. 2.5, Jun. 7, 2021. [Online]. Available: https://www.infineon.com/assets/row/public/documents/24/49/infineon-bsc0901nsi-datasheet-en.pdf

[7] D. Edwards and H. Nguyen, "Semiconductor and IC Package Thermal Metrics," Texas Instruments, SPRA953D, Mar. 2024. [Online]. Available: https://www.ti.com/lit/an/spra953d/spra953d.pdf

[8] Infineon Technologies, "IRFB7430PbF," datasheet, Rev. 2.1. [Online]. Available: https://www.infineon.com/assets/row/public/documents/24/49/infineon-irfb7430pbf-datasheet-en.pdf

[9] Infineon Technologies, "IRFB7530PbF," datasheet, Rev. 2.1. [Online]. Available: https://www.infineon.com/assets/row/public/documents/24/49/infineon-irfb7530pbf-datasheet-en.pdf

[10] Infineon Technologies, "IRFS7730PbF," datasheet, Rev. 2.1. [Online]. Available: https://www.infineon.com/assets/row/public/documents/24/49/infineon-irfs7730pbf-datasheet-en.pdf

[11] Infineon Technologies, "IRLB4030PbF," datasheet, Rev. 2.1. [Online]. Available: https://www.infineon.com/assets/row/public/documents/24/49/infineon-irlb4030pbf-datasheet-en.pdf

[12] S. Widener, "GaN to the Rescue! Part 1: Body-diode Reverse Recovery," Texas Instruments, SSZTC00, Oct. 2015. [Online]. Available: https://www.ti.com/lit/pdf/ssztc00

[13] Vishay General Semiconductor, "SS8PH9, SS8PH10," datasheet, Doc. 88989, Rev. Apr. 24, 2020. [Online]. Available: https://www.vishay.com/docs/88989/ss8ph10.pdf

[14] ON Semiconductor, "MOSFET Thermal Instability in Saturation Operation," AND90187/D, Rev. 0, Jan. 2023. [Online]. Available: https://www.onsemi.com/pub/collateral/and90187-d.pdf

Join the beta waitlist

Be first into the beta, opening Q1 2027. We'll email you when your invite is ready.

No spam, ever. Unsubscribe anytime.